Most enameled wire quotations go wrong for the same reason: the request is missing one of five numbers. This page sets out what each one means, in the order a supplier reads them.
The five things to specify
- Conductor — copper or aluminium, round or rectangular, solid or stranded. Aluminium weighs roughly 30% less than copper for the same volume and carries about 60% of the conductivity, so the two are not interchangeable at the same diameter.
- Bare diameter — in millimetres or AWG, with the tolerance your drawing requires. IEC 60317-0-1 sets tolerances per diameter range; if your drawing is silent, say so and ask what the supplier holds.
- Insulation class — the continuous operating temperature the enamel is rated for: 130, 155, 180, 200 or 220 °C.
- Insulation type — polyurethane (UEW), polyester (PEW), polyester-imide (EIW), polyamide-imide (AIW), or a composite such as EI/AIW.
- Volume and packaging — kilograms per order and per month, spool or reel type, and the lead time you can accept.
Insulation classes at a glance
| Class | Common name | Typical enamel | Typical use |
|---|---|---|---|
| 130 °C | Class B | Polyurethane, polyester | Small motors, transformers, coils |
| 155 °C | Class F | Polyurethane, polyester | Motors, ballasts, relays |
| 180 °C | Class H | Polyester-imide, polyurethane | Motors, transformers, automotive |
| 200 °C | Class 200 | Polyamide-imide, EI/AIW composite | EV traction motors, hermetic compressors |
| 220 °C | Class 220 | Polyamide-imide, composite | Traction, hermetic, high-load duty |
A class number alone does not identify the enamel. Class 155 can be polyurethane or polyester, and the two behave differently on the winding line — one is solderable, the other is not. Always quote the class and the enamel type together.
Which standard to quote
- GB/T 6109 — Chinese national standard, split into parts by insulation type.
- IEC 60317 — the international series most overseas buyers cite.
- NEMA MW 1000 — US practice, AWG sizes and inch-based tolerances.
- JIS C 3202 — Japanese practice.
One line is enough: IEC 60317-20, class 155, UEW, 0.50 mm. Adding the part number removes the ambiguity that a class number alone leaves open.
AWG to millimetres
| AWG | Bare diameter (mm) |
|---|---|
| 18 | 1.024 |
| 20 | 0.812 |
| 22 | 0.644 |
| 24 | 0.511 |
| 26 | 0.405 |
| 28 | 0.321 |
| 30 | 0.255 |
| 32 | 0.202 |
AWG describes the bare conductor only. The insulated overall diameter is larger and depends on the enamel build, so state which of the two your winding window is measured against — it is the most common source of a rejected first sample.
What to send for a quotation
- Conductor material and shape (copper or aluminium; round, rectangular or stranded)
- Bare diameter with tolerance, or AWG size
- Insulation type and thermal class
- Standard and part number, if your drawing cites one
- Quantity: kilograms per order and expected monthly volume
- Spool or reel type and size, and packing requirements
- Delivery port and the lead time you can accept
With those seven lines an enameled wire supplier can quote without a single follow-up question, and you can compare offers on the same basis.